What are the common faults of blood oxygen probe manufactured by blood oxygen probe manufacturers

The number of clicks:
Release date: 2021-01-14 00:00:00
Source: Henan Meilun Medical Electronics Co., Ltd.
share it

What are the common faults of blood oxygen probe manufactured by blood oxygen probe manufacturers

Blood oxygen probe full name as the blood oxygen saturation probe, it is to the human body the blood oxygen saturation and oxygen concentration in the blood were determined a instruments, blood oxygen probe manufacturer produces oxygen probe or perform surgery usually applies to the critically ill patient, service good blood oxygen probe manufacturer is also outstanding medical equipment manufacturing industry, but there is no perfect person, Monitor manufacturerseven good durability blood oxygen probe manufacturer production of blood oxygen sensor has malfunction, so what are the common fault?

1. There is no red emission when the probe is observed

There is no red light emission of the blood oxygen probe produced by the blood oxygen probe manufacturer in the process of use, which is probably caused by defective probe. If the red light emission is normal after replacing the spare probe, it can be preliminarily determined that its probe has faults. The reason for Monitor manufacturersthe defect of the probe is usually the broken wire in the front section of the probe. At this time, it is necessary to cut the sleeve of the wiring area and weld the cable. After the welding is completed, it is tested on the machine until the probe works normally.

Monitor manufacturers

Photocell is extremely insensitive to light

Some blood oxygen probe manufacturer production occurs in the measured blood oxygen probe photocell light induction is not sensitive to fault, fault reason of this may be a photoelectric cell aging or cable circuit, would then tries to set and receive seat cover apart, the roots of photocell measurement, if measurement anomaly, repair it will, don't get attention in the process of repairing the photocell accept face, after the repair test again until SPO2 values back to normal.

Light leakage of probe

Probe light-leaking and blood oxygen probe manufacturer is one of the common faults in the process of production, probe light-leaking to cause a decline in the efficiency of photocell, SPO2 anomalies, and the cause of the probe light-leaking usually as a result of long time use made of soft silicone material probe refers to the set of break, would then use soft silicone material to repair broken hole to restore its good use state.

Oxygen probe is an integral part of clinical medical medical equipment, has an irreplaceable role to the patient's care, blood oxygen sensor manufacturers think about blood oxygen sensor of common faults and fault maintenance is of great significance, blood oxygen sensor manufacturers today described blood oxygen sensor to sum up the common breakdown is the probe itself exists faults, 2 it is to probe the cause of external factors, hope everybody can suit the remedy to the case after reading, find the crux of the malfunction.

What are the common faults of blood oxygen probe manufactured by blood oxygen probe manufacturers